JBD LFP BMS 8S 150A ZP10S036

In Stock

Original price was: ₹3,000.00.Current price is: ₹1,000.00.

WHOLESALE PRICE

  1. Identified for 8S LiFePO4 (LFP) battery pack applications.
  2. Specified 150A current rating; verify continuous and peak current limits.
  3. Supports battery pack monitoring and management.
  4. Helps manage charging and discharging according to its circuit design.
  5. Model reference: ZP10S036.
  6. Verify the supported series configuration and electrical specifications using the product label or datasheet before installation.
In Stock

Did you like this product? Add to favorites now and follow the product.

Add to wishlist

Low Prices

Price match guarantee

Guaranteed Fitment.

Always the correct part

In-House Experts.

We know our products

Easy Returns.

Quick & Hassle Free

Category:
Brand:

Reviews

There are no reviews yet.

Be the first to review “JBD LFP BMS 8S 150A ZP10S036”

Your email address will not be published. Required fields are marked *

Description

The JBD LFP BMS 8S 150A ZP10S036 is a Battery Management System identified for lithium iron phosphate (LiFePO4 or LFP) battery pack applications. It is listed with an 8S configuration and a specified 150A current rating. A Battery Management System is an electronic component that helps monitor and manage the operating conditions of a rechargeable battery pack. It coordinates relevant charging and discharging functions according to the design and capabilities of the circuit. This product is offered for sale under the SUPERWAY brand.

The 8S designation generally refers to eight cells or parallel cell groups connected in series. In an LFP battery pack, the number of series-connected groups determines the overall battery voltage and charging requirements. Selecting a suitable BMS requires matching the battery chemistry, series configuration, current requirements and wiring arrangement. The JBD LFP BMS 8S 150A ZP10S036 is identified for an 8S LFP application, but its actual supported configuration should be confirmed through the product documentation before installation.

The specified 150A rating is an important parameter when selecting a BMS for a particular battery pack. However, the actual continuous and peak current limits depend on the circuit design, electronic components, cooling conditions and installation environment. The stated rating should not automatically be considered a guaranteed continuous operating limit. Check the datasheet for continuous discharge current, charging current, peak current duration and operating temperature limits. The connected battery cells, charger, load, cables and connectors must also be suitable for the intended application.

A Battery Management System helps manage battery operation by monitoring relevant electrical conditions. Depending on the exact circuit design, it may include functions related to cell voltage monitoring, charging control, discharging control, overcurrent response, short-circuit response and temperature monitoring. The exact protection features and operating thresholds must be confirmed for the specific ZP10S036 model. Buyers should consult the product datasheet rather than assume that every possible protection function is included.

Correct installation is essential for proper BMS operation. The battery cells must be arranged in the supported series configuration, and the cell sensing wires must be connected in the sequence specified by the manufacturer. Incorrect wiring or reversed connections can damage the board and other battery components. Before installation, identify the battery positive and negative terminals, cell sensing connections, charging connections and load connections using the correct wiring diagram. Always follow the documentation for the exact model instead of relying on a general BMS connection layout.

The JBD LFP BMS 8S 150A ZP10S036 may be considered for compatible LFP battery pack projects where the verified series configuration and current requirements match the application. LFP battery packs are used in energy storage systems, backup power arrangements and other suitable battery-powered electrical equipment. The suitability of the complete system depends on the battery cells, charger, connected load, wiring, connectors, enclosure and operating conditions.

One specification requires particular attention before purchase or installation. The product name identifies an 8S configuration, while the model reference ZP10S036 contains a 10S indication. The model code alone does not establish that the board supports an 8S battery pack. Confirm the actual number of supported series-connected cell groups from the product label or manufacturer datasheet. Do not connect the board to an 8S battery pack until this detail has been verified.

SUPERWAY is the selling brand for this product. The JBD name and ZP10S036 reference are retained as product identification details, while SUPERWAY is the brand under which the product is offered for sale. Buyers should check the exact model marking, connector layout, wiring diagram, supported battery configuration and electrical ratings before selecting the board.

For a suitable battery installation, use compatible LFP cells, an appropriate charger and correctly rated cables and connectors. Keep the BMS and battery pack within their documented operating conditions. Avoid modifying the electronic circuit or changing its wiring arrangement without reliable technical documentation. A qualified battery technician should verify the battery configuration, polarity and connections before the system is put into operation.

The JBD LFP BMS 8S 150A ZP10S036 is identified by its 8S LFP product description and specified 150A rating. Its actual series compatibility and operating limits must be confirmed using the product documentation, especially because the model reference contains a 10S indication. Checking these details helps ensure that the BMS is correctly matched with the battery pack and connected equipment.