  1. Designed for 19S LiFePO4 battery pack configurations.
  2. Specified 40A current rating.
  3. Supports battery pack monitoring and management.
  4. Helps manage charging and discharging operations.
  5. Intended for compatible 60.8V nominal LiFePO4 battery systems.
  6. Check wiring, connection layout, and electrical specifications before installation.
In Stock

Did you like this product? Add to favorites now and follow the product.

Add to wishlist

Low Prices

Price match guarantee

Guaranteed Fitment.

Always the correct part

In-House Experts.

We know our products

Easy Returns.

Quick & Hassle Free

Category:
Brand:

Reviews

There are no reviews yet.

Be the first to review “DALY BMS LFP 19S 40A”

Your email address will not be published. Required fields are marked *

Description

The DALY BMS LFP 19S 40A is a Battery Management System designed for 19-series LiFePO4 (Lithium Iron Phosphate) battery pack configurations. It is intended to support battery pack management by helping monitor and control important electrical operating conditions during charging and discharging. With a specified 40A current rating, this BMS is intended for compatible battery applications where the required configuration and electrical ratings match the product specifications.

A 19S LiFePO4 battery pack consists of 19 cells or parallel cell groups connected in series. Each LiFePO4 cell has a nominal voltage of approximately 3.2V, giving a 19S configuration a nominal pack voltage of approximately 60.8V. The actual charging voltage, operating range, and other electrical limits must be confirmed using the battery cell specifications and BMS documentation. Selecting the correct series configuration is important because the BMS must match the battery pack architecture.

The specified 40A rating is an important factor when selecting a Battery Management System for a lithium battery project. However, this rating should not automatically be treated as a guaranteed continuous operating current. Continuous and peak current limits, charging current, discharge capability, temperature limits, and other operating conditions should be checked against the manufacturer’s datasheet. The BMS should be selected according to the electrical requirements of the complete battery system.

Battery Management Systems help manage battery pack operation. Depending on the circuit design and model specifications, a BMS may monitor individual cell-group voltages and battery operating conditions and control charging or discharging when configured limits are reached. The exact protection functions available on this particular model should be confirmed from its product documentation rather than assumed from the general term BMS.

The DALY BMS LFP 19S 40A is intended for compatible LiFePO4 battery pack projects. Potential applications may include battery storage systems, compatible inverter battery packs, backup power systems, and other equipment designed around a suitable 19S LiFePO4 configuration. Application suitability depends on battery design, voltage requirements, current demand, wiring arrangement, and the specifications of the connected equipment.

When selecting this product, check the battery chemistry first. LiFePO4 and other lithium battery chemistries have different voltage characteristics and charging requirements. A BMS designed for LiFePO4 should not be selected solely because its series count or current rating appears suitable for another battery chemistry. Confirm that the battery cells, charger, inverter, and BMS are designed to operate together.

Installation requires attention to the battery connection sequence, cell-group wiring, power connections, cable size, and terminal arrangement. Incorrect wiring can cause malfunction or damage to the BMS and connected battery components. Follow the manufacturer’s wiring diagram and installation instructions. Have the battery system checked by a qualified technician before operation.

It is also important to verify the physical dimensions, connector arrangement, wire configuration, and mounting requirements before purchasing. BMS products with similar series counts and current ratings may have different layouts or connection methods. The product label and datasheet should be used to confirm the exact model and its compatibility with the intended battery pack.

The DALY BMS LFP 19S 40A is sold under the SUPERWAY brand. SUPERWAY offers this product for customers working with compatible lithium battery components and battery pack assemblies. The DALY name is retained in the product identification, while SUPERWAY is the selling brand for this listing.

Before using the BMS, verify the 19S configuration, LiFePO4 chemistry, specified 40A rating, charging and discharging limits, protection settings, and wiring requirements. Also confirm that the charger and connected equipment support the battery pack’s actual voltage range. Proper component selection and installation are essential for dependable battery system operation.

Choose the DALY BMS LFP 19S 40A when your battery project specifically requires a compatible 19-series LiFePO4 Battery Management System with the specified 40A rating. Checking the manufacturer’s technical documentation before installation helps ensure that the BMS matches the battery pack and the requirements of the complete electrical system.